CHAPTER 1 GENERAL INFORMATION
System Conditions
SYSTEM CONDITIONS
Only one PIM configuration is available at the Remote Site.
Remote PIM can be installed at a maximum of 400 m (1312 ft.) distance from the Main Site.
Using the Optical Interface card (PN-M10) or line extension equipment (Repeater, MUX,
etc.), the distance can be extended.
At the Remote Site, the line/trunk cards can be used as same as the Main Site.
For North America, the line/trunk cards, except the CSI card for wireless system according
to UTAM regulation, can be used.
The application processor cards cannot be used at the Remote Site. When you provide the
ILC or CSI card to the Remote Site, the ICH or CSH card must be installed on the Main Site.
For Remote PIM System, the installation procedures for modules, circuit cards, and periph-
eral equipment are the same as those for the regular system, except the DAI cards instal-
lation and the BUS cable connection.
Refer to the Installation Procedure Manual for detailed information.
When the link between the Main Site and Remote Site has been lost due to power failure or
PCM Frame Loss, the system activates the Power Failure Transfer (PFT) automatically on
the Remote Site, if provided.
The Resident System Programming cannot be set to the Remote Site while the Main Site
can be set.
If ILC or COTB card is mounted in Remote PIM, the T1 link between main and Remote Sites
must be configured as 64 Kbps with ESF and B8ZS.