CHAPTER 3 TROUBLESHOOTING
PN-DAIE
(DAIE)
RUN lamp is not
flashing.
Abnormal operation
of DAIE card
1 Reset the MB switch.
(DownUpDown)
2 If the fault cannot be
cleared, replace the card.
LINK lamp is not on. Layer 2 link connec-
tion failure between
DAID and DAIE
1 Check to see if the cable
between DAID and DAIE is
correctly connected. Refer
to "Connection Between
Main Site and Remote Site"
on Page 47.
2 Reset the MB switch.
(DownUpDown)
RMT lamp is on. Remote alarm Check to see if the cable
between DAID and DAIE
(sending side) is correctly con-
nected. Refer to "Connection
Between Main Site and
Remote Site" on Page 47.
Table 3-1 Remedial Action on Each Lamp Status (Continued)
CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION