Emerson 400501-08 Wireless Office Headset User Manual


 
25
Configuring the DeviceNet Network
DN Comm Time-out Fault Count
Ei-DN Modbus Address: 40717
This parameter indicates the total # of Communication Time-out Faults that have occurred on the
DeviceNet network.
DN Device Type
Ei-DN Modbus Address: 34002
DN Device Type indicates the ODVA (Open DeviceNet Vendors Association) definition for
devices. The Ei-DN is set at a DN Device Type of 0.
DN Duplicate MacID Fault Count
Ei-DN Modbus Address: 40718
The DN Duplicate MacID Fault Count indicates the total number of duplicate MacID faults that
have occurred on the DeviceNet network.
DN FAB Master Receive Block
Ei-DN Modbus Address: 34011-34014
The DN FAB Master Receive Block displays the polled data being transferred from the drive to
the master via the Master Receive fixed assembly block (FAB).
Range Units Default Type DN Type Group NVM Res. Access
0-2
15
-1 Counts US16 UINT Yes RO
Range Units Default Type DN Type Group NVM Res. Access
US16 UINT No RO
Range Units Default Type DN Type Group NVM Res. Access
0-2
15
-1 Counts US16 UINT Yes RO
Range Units Default Type DN Type Group NVM Res. Access
US16 UINT No RO
Word Modbus Address
034011
1 34012
2 34013
3 34014