10
Epsilon Ei DeviceNet Drive Reference Manual
Figure 4: The DeviceNet Setup Tab
MacID
The MacID is the number assigned to a particular node. Every node on a DeviceNet network
must have a unique MacID. The range is 0-63. The MacID is also read/write accessible with
the one-touch configuration described in “Setting the Baud Rate and MacID Externally (One
Touch)” on page 32.
Baud Rate
Three standard baud rates can be configured for the DeviceNet network: 125K, 250K, and
500K. The baud rate is also read/write accessible with the one touch configuration described
in “Setting the Baud Rate and MacID Externally (One Touch)” on page 32.
Master Receive and Master Send Assembly Block Selections
In PowerTools FM the user is given the option to select from 9 predefined assembly blocks.
Master Receive Assembly Block data translates to 8 bytes of Polled I/O data that will be
transferred from the Ei-DN to the Master via DeviceNet, and Master Receive Assembly
Block data translates to 8 bytes of polled I/O data that will be transferred from the Master to
the Ei-DN.
Index Select Predefined (Index Sel (Predef))
Index Sel (Predef) is a fixed assembly block used for reading and writing basic functions to
and from the Ei-DN. This fixed assembly block is the default selection in PowerTools FM