Tone Configuration Parameters
ReorderTone Parameter Example 2
Assume that you want a reorder tone in which:
The only frequency is 400 Hz.
The frequency plays six times, each time for 0.1 second followed by 0.9 second of silence.
The frequency then plays once for 0.3 second followed by 0.7 second of silence.
The volume of the frequency is –19 dBm.
The tone plays until another call event stops the tone.
For this reorder tone, make the following setting. See Table 5-6 for a detailed explanation.
ReorderTone:100,1,31164,1620,0,0,0,0,2,800,7200,2400,5600, 0,0,5,0
NumOfRepeats 0 First on-off pair of the cadence plays once
(does not repeat), then the second on-off pair
plays
TotalToneTime 0 Tone plays continuously (set of three on-off
pairs of the cadence repeat continuously) until
another call event stops the tone
Table 5-5 Reorder Tone Parameter Example 1 Explanation (continued)
Component Setting Explanation
Table 5-6 Reorder Tone Parameter Example 2 Explanation
Component Setting Explanation
Sequential 100 Required setting for a tone with one frequency
NumOfFreqs 1 One frequency in the tone
TFreq1 31164 First frequency is 400 Hz
TAmp1 1620 First frequency volume is –19 dBm
TFreq2 0 No second frequency
TAmp2 0 No second frequency
TFreq3 0 No third frequency
TAmp3 0 No third frequency
NumOfOnOffPairs 2 Two on-off pairs in the cadence of the tone
OnTime1 800 Sound in first on-off pair plays for 0.1 second
OffTime1 7200 Sound in first on-off pair is followed by 0.9
second of silence
OnTime2 2400 Sound in second on-off pair plays for 0.3
seconds
OffTime2 5600 Sound in second on-off pair is followed by 0.7
second of silence
OnTime3 0 No third on-off pair in the cadence
OffTime3 0 No third on-off pair in the cadence