Avaya 4600 IP Phone User Manual


 
Server Administration
82 4600 Series IP Telephone Release 2.2 LAN Administrator Guide
OPSTAT 111 Options status flags. Consists of 3 “bits” of the form
abc, where each letter represents a 0 (disabled/off)
or 1 (enabled/on). The first bit, a, controls the setting
for all options not controlled by the second or third
bits. The second bit, b, controls the setting for
view-oriented options (for example, the 4620’s View
IP Settings option), if applicable. The third bit, c,
controls the setting for the LOGOFF option, if
applicable.
PHNCC 1 Telephone country code. The administered
international country code for the location of the
serving MultiVantage
server. Range: 1-3 digits,
from “1” to “999”.
PHNDPLENGTH 5 Telephone dial plan length. The length of the
administered dial plan for the serving
MultiVantage
server. Range: 1 or 2 digits, from “3”
to “10”.
PHNIC 011 Telephone international access code. The digits
dialed to access public network international trunks
from the serving Multi-Vantage
server. Range: 1-4
digits.
PHNLD 1 Telephone long distance access code. The digit
dialed to access public network long distance trunks
from the serving MultiVantage
server. Range: 1
digit or " " (Null).
PHNLDLENGTH 10 Length of national telephone number. The number of
digits in the longest possible national telephone
number for the serving Avaya media server’s
location. Range: 1 or 2 digits, from “5” to “15”.
PHNOL 9 Outside line access code. The character(s) dialed to
access public network local trunks from the serving
Avaya media server. Range: 0-2 dialable characters,
including " " (Null).
PHY1STAT 1 Ethernet line interface setting (1=auto, 2=10Mbps
half-duplex, 3=10Mbps full-duplex, 4=100Mbps
half-duplex, 5=100Mbps full-duplex).
PHY2STAT 1 Secondary Ethernet interface setting
(0=Secondary Ethernet interface off/disabled,
1=auto, 2=10Mbps half-duplex, 3=10Mbps
full-duplex, 4=100Mbps half-duplex, 5=100Mbps
full-duplex).
Table 6: 4600 Series IP Telephone Customizable System Parameters (continued)
Parameter
Name
Default
Value
Description and Value Range
3 of 4