Message Description Action
Incorrect Security settings.
Verify that all the Security settings in the
handset match those in the APs.
No Net Found
xxxxxxxxxxxx yy
x…x = AP MAC address.
yy = AP signal strength.
Handset cannot find a suitable AP;
displays MAC and signal strength of
“best” non-suitable AP found.
Check AP and handset network settings
such as ESSID, Security, Reg domain
and Tx power.
Ensure APs are configured per
Configuration Guide.
Try Site Survey mode to determine a
more specific cause.
No PBX Response
The handset has exceeded its
retransmission limit with no ACK
response from proxy server.
Verify that proxy server IP address and
port are properly configured.
No Reg Domain Regulatory Domain Not Set.
Configure the Regulatory Domain of the
handset.
No SIP TFTP IP
No IP address has been entered for
the SIP TFTP server.
In static IP mode the SIP TFTP server
address must be entered in the
administrative menus.
No SIP user file
The phone is attempting to download a
SIP configuration file from the SIP
TFTP server. A file must be available
for the username that was entered
either in the admin menus or as
requested at power-on.
Ensure a SIP configuration file is
available on the SIP TFTP server and is
named as specified (sip_username.cfg).
No SVP IP
The handset is configured for “Static
IP” (as opposed to “use DHCP”), and
no valid SpectraLink 8000 SVP Server
address has been entered.
Enter a valid SpectraLink 8000 SVP
Server IP address in the configuration
setting or change to “use DHCP.”
No SVP Response
yyy.yyy.yyy.yyy
y…y = SVP Server IP address.
Handset has lost contact with the SVP
Server.
This may be caused by bad radio
reception or a problem with the
SpectraLink 8000 SVP Server. The
handset will keep trying to fix the
problem for 20 seconds, and the
message may clear by itself. If it does
not, the handset will restart. Report this
problem to the system administrator if it
keeps happening.
No SVP Server
Handset can’t locate SpectraLink 8000
SVP Server.
IP address configuration of SpectraLink
8000 SVP Server is wrong or missing.
SpectraLink 8000 SVP Server is not
working.
Check error status screen on
SpectraLink 8000 SVP Server.
No LAN connection at the SpectraLink
8000 SVP Server.
Verify SpectraLink 8000 SVP Server
connection to LAN.
No SVP Server
No DNS Entry
Handset unable to perform DNS
lookup for SVP Server, server had no
entry for SVP Server.
The network administrator must verify
that a proper IP address has been
entered for the SVP Server DHCP
option.