Peerless Industries KX-TDA200 IP Phone User Manual


 
3.3 PT Programming
350 Feature Guide
CLIP/COLP Number [606]
Incoming Call Distribution Group Member [620]
Incoming Call Distribution Group Delayed Ringing [621]
Incoming Call Distribution Group Floating Extension Number [622]
Incoming Call Distribution Group Name [623]
Incoming Call Distribution Group Distribution Method [624]
[606]
Max. 16 digits
CLIP/COLP No.
1–4 digits
END
ENTER ENTER
Extn. No.
[620]
01–32
Location No.
1–4 digits
01–64
Incoming Call
Distribution
Group No.
END
ENTER
ENTER
Extn. No.
[621]
01–32
Location No.
END
Immediate/
1–6 (rings)/
No ring
SELECT
ENTER
ENTER
01–64
Incoming Call
Distribution
Group No.
[622]
1–4 digits
END
ENTER
ENTER
Extn. No.
01–64
Incoming Call
Distribution
Group No.
[623]
Max. 20 characters
Name
END
ENTER ENTER
01–64
Incoming Call
Distribution
Group No.
[624]
END
Ring/UCD/
Priority Hunt
SELECT
ENTER
ENTER
01–64
Incoming Call
Distribution
Group No.