51
9
INSTALLATION AND CONNECTIONS
62
� AT-180 internal switch description
The optional AT-180 has 3 operating conditions for
HF band operation. Select a suitable condition
according to your antenna system.
qRemove the top cover of the AT-180.
wSet the tuner switches to the desired positions
according to the table below.
•Speci cations for the AT-180
•Frequency coverage : 1.9–54 MHz
•Input impedance : 50 Ω
•Maximum input : 120 W
power
•Minimum tuning : 8 W
power
•Matching impedance : 16.7–150 Ω
(HF band)
range 20–125 Ω (50 MHz band)
•Tuning accuracy : Less than SWR 1.5:1
•Insertion loss : Less than 1.0 dB
(after tuning)
•Power supply : 13.8 V DC/1 A (supplied from
requirements the transceiver’s ACC socket)
•Dimensions (mm/in) : 167(W)× 58.6(H)× 225(D)
6
9
⁄
16
(W)× 2
5
⁄
17
(H)× 8
7
⁄
8
(D)
•Weight : 2.4 kg; 5 lb 4 oz
•Supplied accessories: coaxial cable (1 m),
ACC cable (DIN 13 pins)
•AT-180 inside top cover
•Connector information for ACC(2) socket
S2 S1
D C B A
ACC 2
1
2
3
4
76
5
PIN NO./
NAME
DESCRIPTION
q8 V
Regulated 8 V output.
(10 mA max.)
wGND
Connects to ground.
eSEND
Input/output pin.
Goes to ground when transmitting (20 mA
max). When grounded, transmits.
rBAND
Band voltage output.
(Varies with amateur band; 0 to 8.0 V).
tALC
ALC output voltage (–4 to 0 V).
yNC
No connection.
u13.8V
13.8 V output when power is ON (1 A max).
SW Position Operation
S1
A
(default)
The tuner operating condition is set by S2
described below.
B
THROUGH INHIBIT
The tuner tunes the antenna even when
the antenna has poor SWR (up to VSWR
3:1 after tuning). In this case, manual tun-
ing is necessary each time you change the
frequency although the tuner automatically
starts tuning when the VSWR is higher
than 3:1. This setting is called “through
inhibit,” however, the tuner is set to
“through” if the VSWR is higher than 3:1
after tuning.
S2
C
TUNER SENSITIVE CONDITION
The tuner tunes each time you transmit
(except SSB mode). Therefore, the lowest
SWR is obtained at any given time.
For SSB mode, the same condition is as
D
(default)
NORMAL CONDITION
The tuner tunes when the SWR is higher
than 1.5:1. Therefore, the tuner activates
only when tuning is necessary.
10
OPTIONAL INSTALLATIONS/SETTINGS
the “D” position below.