Toshiba DK40I Telephone User Manual


 
ISDN
Program *43-2 Non-Facility Associated Signaling (NFAS) Assignment
7-18 Strata DK Programming 5/00
Program *43-2 Non-Facility Associated Signaling
(NFAS) Assignment
Processor Type: DK40i, all RCTUs (Release 4.0 or higher) and BCUs
Program Type: System, PRI
Initialized Default: Blank (see Note and Important! below)
Program *43-2 Overview
This program specifies the card slot of additional PRI links that are dependent upon the D-channel
of the master D-channel PRI. This setting is for Non-Facility Associated Signaling (NFAS).
Use the Record Sheet for *43-1.
Guide to Programming NFAS with Release 4.15 software
Program *42 XX (slot) X (circuit) Only assign the first PRI slot.
Program *43 1 X (PRI Index) XX (D-channel)
Note Normally, 01 is provided by the carrier to define the second span, but in some instances as
in a DMS, the carrier uses 01 to define a backup D-channel and 02 defines 47b+d. You
need to confirm this with the carrier prior to installation.
 
6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
PRI Index
*43-1
D-Channel
Circuit Number
*43-2
Master PRI
Index
*43-3
Network PRI Interface
ID Code
124100
2 1 01 or 02
Enter the dependent PRI Index
Number without D-channel (1~8)
PRI = Master PRI Index
Number with D-channel (1~8)
SEL = 2