Cisco Systems SPA9000 IP Phone User Manual


 
6-28
Linksys SPA9000 Administrator Guide
Document Version 3.01
Chapter 6 SPA9000 Field Reference
Regional Tab
Control Timer Values (sec)
Field Description
Hook Flash Timer Min Minimum on-hook time before off-hook qualifies as hook-flash. Less than this the
on-hook event is ignored. Range: 0.1–0.4 seconds.
The default is 0.1.
Hook Flash Timer Max Maximum on-hook time before off-hook qualifies as hook-flash. More than this the
on-hook event is treated as on-hook (no hook-flash event). Range: 0.4–1.6 seconds.
The default is 0.9.
Callee On Hook Delay Phone must be on-hook for at this time in sec before the SPA9000 will tear down the
current inbound call. It does not apply to outbound calls. Range: 0–255 seconds.
The default is 0.
Reorder Delay Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =
never plays. Range: 0–255 seconds.
The default is 5.
Call Back Expires Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
The default is 1800.
Call Back Retry Intvl Call back retry interval in seconds. Range: 0–255 seconds.
The default is 30.
Call Back Delay Delay after receiving the first SIP 18x response before declaring the remote end is
ringing. If a busy response is received during this time, the SPA9000 still considers the
call as failed and keeps on retrying.
The default is 0.5.
VMWI Refresh Intvl Interval between VMWI refresh to the CPE.
The default is 0.5.
Interdigit Long Timer Long timeout between entering digits when dialing. The interdigit timer values are used
as defaults when dialing. The Interdigit_Long_Timer is used after any one digit, if all
valid matching sequences in the dial plan are incomplete as dialed. Range: 0–64 seconds.
The default is 10.
Interdigit Short Timer Short timeout between entering digits when dialing. The Interdigit_Short_Timer is used
after any one digit, if at least one matching sequence is complete as dialed, but more
dialed digits would match other as yet incomplete sequences. Range: 0–64 seconds.
The default is 3.