196953 0x30159 MINOR Password authentication failure;
may need to configure or
application restart.
The password authentication
feature is not working.
Recommended Action:
Check for an LDAP
configuration problem or an
LDAP server failure. Try
restarting the application.
196959 0x3015F INFO No voice conferencing licenses
are installed.
The system has a web
conferencing license installed
but no voice conferencing
license.
Recommended Action:
Install voice conferencing
licenses.
458788 0x70024 MAJOR Module timed out on “are you
there” query, class=##
One of the major software
modules (identified by the
class number) failed to
respond to a query from the
system integrity manager
(SIM). This restarts the
system.
Recommended Action:
Report all such occurrences to
Cisco TAC for problem
diagnosis.
458889 0x70089 WARN Stopping exception log due to
flooding.
The exception logging process
stops logging if incoming
messages exceed a certain rate.
This prevents the logging
mechanism from stealing
critical resources when the
system is overloaded.
Recommended Action:
No action required.
458890 0x7008A INFO Lost ## exception events;
logging resumed.
The exception logging process
dropped the indicated number
of messages due to overload.
Normal logging has now
resumed.
Recommended Action:
No action required.