ADTRAN 3000 Answering Machine User Manual


 
Appendix A. AT Commands and S-Registers
A-10 Express 3000 User Manual 61203153L2-20
S08 Call Rejection
Determines which incoming voice calls the Express 3000
will reject.
0=Disables
1=Reject anonymous calls only
2=Reject calls on call rejection list only
3=Reject anonymous and call rejection list numbers
S12 Escape Time
Determines the delay required immediately before and
after entering the escape command for the Express 3000 to
recognize and execute the command.
Range = 0 to 127
S13 Spid Download
Enable/Disable
0=Enabled
1=Disabled
S14 Misc Bits
Miscellaneous bits (bit 8 is most significant bit).
Bit 2 = 1:Enables on screen echo of AT commands.
Bit 2 = 0:Disables on screen echo of AT commands.
Bit 3 = 0:Enables AT responses from the
Express 3000.
Bit 3 = 1:Disables AT responses from the Express 3000.
Bit 4 = 1:Enables AT responses to be displayed in text
form.
Bit 4 = 0:Enables AT responses to be displayed in numeric
form.
Bit 7 = 1:Disable PPP ACCM spoofing.
Bit 7 = 0:Enable PPP ACCM spoofing.
Bit 8 = 1:Ring indicator uses cadence.
Bit 8 = 0:Ring indicator remains on.
S15 Async
Bonding
Asynchronous BONDING method.
0 = ADTRAN revision 0 (default)
1 = Multi-vender option
S19 Miscellaneous
POTS
POTS features bit mapped register.
Bit 0 = Set: Distinctive ring on.
Bit 1 = Set: Busy/Ring for POTS Port 1
Bit 2 = Set: Busy/Ring for POTS Port 2
Bit 3 = Set:
Bit 4 = Set:
Bit 5 = Set: Disables call waiting for POTS Port 1.
Bit 6 = Set: Disables call waiting for POTS Port 2.
Bit 7 = Set:
S20 Read POTS
Debug only.
S21 Write POTS
Debug only.
S-Registers List
(Continued)
Command
Function Features