Panasonic KX-TDA30 IP Phone User Manual


 
4.1 Troubleshooting
160 Installation Manual
PROBLEM PROBABLE CAUSE SOLUTION
Cannot register the PS. Wrong Personal
Identification Number
(PIN) is registered to the
PS.
Register the PIN set to the Hybrid IP-
PBX into the PS.
CS is not connected
properly.
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
PS becomes out of
range.
Cannot make calls using
the PS.
CS is not working. Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Location of CS is not
good.
Locate the CS properly (refer to "2.7.5
Site Survey Using the KX-TD7590" or
"2.8.5 Site Survey" ).
Access system of the
PS is not properly set.
Change the access system setting of
the PS to the appropriate system or
automatic.
Noise is frequent while
using the PS.
Conversations
disconnect while using
the PS.
Call handover is not
working.
PS is out of CS coverage
area.
Locate the CS properly (refer to "2.7.5
Site Survey Using the KX-TD7590" or
"2.8.5 Site Survey" ).
PS stays out of service
when the CS status is
changed from Out of
Service to In Service.
It may take about 20 s
for CS to start up after
the status has been
changed to In Service.