Panasonic KX-TDA30 IP Phone User Manual


 
2.8 Connection of 2.4 GHz Portable Stations
108 Installation Manual
2.8 Connection of 2.4 GHz Portable Stations
2.8.1 Overview
The following equipment is required to connect the wireless system:
CS: Cell Station (KX-TDA0141)
This unit determines the area covered by the wireless system. Up to 2 calls can be made at
the same time through each CS.
PS: 2.4 GHz Portable Station (KX-TD7690/KX-TD7680)
The KX-TDA30 can support up to 28 PSs. For more details about the PS, refer to the PS
Operating Instructions.
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40 °C),
low temperature (less than 0 °C), vibration, and should not be exposed to direct
sunlight.
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high voltage equipment.
The CS should not be placed on a metal object.
Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere
with the KX-TDA wireless system. Examples of such systems are cordless
telephones, wireless LAN, Home RF, microwave ovens and other ISM devices. These
systems may cause minor noise.
Keeping some distance between the equipment listed below may prevent
interference. (The distance may vary depending on the environment.)
Equipment Distance
CS and office equipment such as a computer, telex,
fax machine, etc.
More than 2 m
CS and PS More than 1 m
Each PS More than 0.5 m
Hybrid IP-PBX and CS More than 2 m
CS and CS More than 15 m
Please take into consideration the distance between the CSs when site planning.
Please consult a certified dealer for details.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.