NEC 120 Answering Machine User Manual


 
AD-25182501 CHAPTER 3
Page 85
Revision 1.0.1
NAP- 200-007
Sheet 22/42
Termination of Cables on MDF
(4) Single Line Telephone (SLT)
(a) Standard Line (PN-4LCE/4LCF)
Figure 007-9 MDF Cross Connection for a Single Line Telephone (Standard Line)
29T3 29
4
R3 4
28
T2 28
3
R2 3
27
T1 27
26
T0 26
2
1
1R026T0
2R127T1
3R228T2
4R329T3
(P)
26 T0 1 R0
27 T1 2 R1
28 T2 3 R2
29 T3 4 R3
LEN0000
LEN0001
LEN0002
LEN0003
LTC0 (J)
MDF
R0 1
R1 2
LEN0000 (No. 0)
PIM0
PPN-4LCE/4LCF
LT00
LTC0
J
LEN0001 (No. 1)
LEN0002 (No. 2)
LEN0003 (No. 3)
TO SINGLE
LINE TELEPHONE