Installation of Main Equipment
2.1 Cable Connections and Switch Settings on PZ-PW86
Note:
This version is now obsolete.
WARNINGS, RE MODE SWITCH
:
1. SEGMENT 1: Set to ON.
2. SEGMENT 2: Set to ON (left) only, which is 27 volts (FLOAT). The OFF setting is 28 volts (EQUALIZE),
to be used only
for periodic boost-charging of EXTERNAL VENTED batteries.
3. This unit is best suited to sealed batteries; the preferred item for vented batteries is PZ-PW86(A).
Figure 003-23 Cable Connections and Switch Settings on PZ-PW86
MJ
MN
ON
GND
See
FG
-27V
PWR CNT CA-A
PWR CA-A
BATTERY CABLE/PWR CA-A
TO PWR1
TO OTHER
AC CORD-A
TO AC MAINS INPUT
TO
TO PWR0A CONNECTOR
TO PWR0B CONNECTOR
CONNECTOR
PZ-PW86
TO AUXILIARY
BATT2
BATT1
SW
I
ON
OFF
O
100/
240V
AC INPUT
EQUIPMENT
TO BATTERY OR
OTHER PZ-PW86
GREEN/YELLOW
BLUE
BROWN
TERMINAL ON THE CHASSIS
Set the appropriate voltage before turning on
the AC switch.
CAUTION
Note 2:
In Australia, GND and FG are bonded
elsewhere, so are not to be linked here.
The TRC Earth connects to the “GND”
terminal on every PIM.
Note 1:
Set to ON for
normal operation.
*
*
Cabling method is determined by usage of internal or external battery. See NAP-200-005.
RINGER OUTPUT
CABLE (CR,E)
POWER OUTPUT
CABLE (+5V, -27V, E)
ON
1
2
AC/BATTERY SWITCH
MODE
MAX: 2.5A DC
120V
AC
AC
Note 2