The table below describes all fields in the PhoneBook Configuration screen.
PhoneBook Configuration Parameter Definitions
Field Name Values Description
Gateway Name Y/N This field allows you to specify a name for this
MultiVOIP. When placing a call, this name is
sent to the remote MVP3000 for display in Call
Progress listings, Logs, etc.
Q.931 Parameters
Use Fast Start Y/N Enables the H.323 Fast Start procedure. May
need to be enabled/disabled for compatibility
with third-party VOIP gateways.
Call Signaling
Port
port
number
Default: 1720 (H.323)
GateKeeper RAS
Parameters
Gatekeeper /
Clear Channel
IP Address
IP address of the GateKeeper.
Port Number Well-known port number for GateKeepers.
Must match port number of GateKeeper, 1719.
Gateway Prefix This number becomes registered with the
GateKeeper. Call requests sent to the gatekeeper
and preceded by this prefix will be routed to the
VOIP gateway.
Gatekeeper
Name
alpha-
numeric
string
Optional. The name of the GateKeeper with
which this MultiVOIP is trying to register.
Gateway H.323
ID
The H.323 ID is used to register this particular
MultiVOIP with the GateKeeper. H.323 ID is an
alias entry sent to the GateKeeper, made of
alphanumeric characters. For NetMeeting
endpoints, numbers are preferred over letters.
The H.323 ID identifies the IP calling sequence
that the GateKeeper must ‘dial’ to contact the
remote VOIP.