Multi-Tech Systems MVP-2410 IP Phone User Manual


 
MultiVOIP User Guide Technical Configuration (Analog/BRI)
231
FXO Interface: Parameter Definitions (cont’d)
Field Name Values Description
Dialing Options (cont’d)
Inter Digit
Regeneration
Time
milliseconds The length of time between the
outputting of DTMF digits.
Default = 100 ms.
FXO Disconnect On There are three possible criteria for
disconnection under FXO: current
loss, tone detection, and silence
detection. Disconnection can be
triggered by more than one of the
three criteria.
Current Loss Y/N
Disconnection to be triggered by
loss of current. That is, when
Current Loss is enabled (“Y”), the
MultiVOIP will hang up the call
when it detects a loss of current
initiated by the attached device.
FXO Current
Detect Timer
integer values
(in milliseconds )
The minimum time required for
detecting the current loss signal on
the FXO interface. In other words,
this is the minimum length of time
the current must be absent to
validate ‘current loss’ as a
disconnection criterion. Default =
500 ms.
Tone Detection Y/N Disconnection to be triggered by a
tone sequence.