Lucent Technologies 7400B Telephone User Manual


 
DEFINITY Communications System
APPENDIX B: S-REGISTERS
7400B Data Module
User’s Guide
Page B-7
Register:
S7
Description: Wait time for line signal or dial tone. If line signal is not detected
within this time, the call will be disconnected.
Range of Value may be 001 through 055 seconds; factory-default value is 030
Values:
seconds.
Storable:
no
Comments: This register will affect only the wait time for line signal detection.
The 7400B always waits the length of time in register S7 for the
equivalent of a dial tone from the PBX.
See Also:
Chapter 4, “Operation and Configuration.”
Register:
S8
— not used
Register:
S9
— not used
Register:
S10
Description:
The value in this S-register determines how long the 7400B Data
Module will wait after loss of line signal is detected before
disconnecting.
Range of Value may be 000 through 255 tenths (0.1) of a second; factory-default
Values:
value is 014 tenths of a second (1.4 sec.).
Storable:
no
Comments:
The delay set by this S-register allows the receive line signal to
disappear momentarily without causing a disconnect (hang-up).
Setting this S-register to the maximum value (255) causes the Data
Module to ignore receive line signal status and not disconnect the data
call if line signal is lost.
See Also:
Chapter 4, “Operation and Configuration.”