DEFINITY Communications System
APPENDIX A: AT COMMAND SET
7400B Data Module
User’s Guide
Page A-11
Command:
Z
Function:
Reset and recall a stored profile.
Type:
immediate
Arguments:
No argument or an argument of 0 recalls the configuration profile
stored in location 0; an argument of 1 recalls the configuration profile
stored in location 1.
S-Register:
none
Example:
atz1
[ Enter ]
Comments:
In the example, the z command causes the 7400B Data Module to
reset, and then loads the configuration profile stored in location 1 into
the active location.
See Also:
Chapter 4, “Operation and Configuration.”