DEFINITY Communications System APPENDIX A: AT COMMAND SET
7400B Data Module
User’s Guide
Page A-17
Command:
Function:
Type:
Arguments:
S-Register:
Example:
Comments:
at&w0
[ Enter ]
See Also:
&W
Store the active configuration profile.
immediate
No argument or an argument of 0 stores to location 0, an argument of 1
stores to location 1.
none
In the example, the currently active configuration profile is stored to
memory location 0. Only a subset of the configuration parameters are
actually stored.
Chapter 4, “Operation and Configuration”; Appendix B, “S-
Registers.”
Command:
&Y
Function:
Designate the default configuration profile.
Type:
configuration
Arguments:
An argument of 0 will recall stored profile 0; an argument of 1 will
recall stored profile 1. Factory-default selection is stored profile 0.
S-Register:
none
Example:
at&y1
[ Enter ]
Comments: In the example, the configuration profile stored in location 1 will be
recalled the next time that the 7400B Data Module is powered on.
When the &Y command is issued, the currently active profile does not
change until the data module is powered off and then on again.
See Also: Chapter 4, “Operation and Configuration.”