Lucent Technologies 555-235-100 IP Phone User Manual


 
4 Messaging Integration
DEFINITY ProLogix Solutions Release 2 Overview
555-235-100 Issue 2 June 1999 4-3
Messaging Integration
INTUITY AUDIX
DEFINITY ProLogix Solutions supports the following integration methods for use with the Lucent
INTUITY systems:
LAN Link
Mode Code (in band) communications
LAN Link The LAN link allows the DEFINITY ProLogix Solutions system and the Lucent
INTUITY system to communicate over a private, dedicated LAN or using a
customer’s LAN. The DEFINITY ProLogix Solutions system is a server, and the
Lucent INTUITY system is a client that always initiates the communications session.
This link uses a LAN circuit card installed in the Lucent INTUITY system and a C-
LAN circuit pack (TN799) installed in the DEFINITY ProLogix Solutions system.
The two systems use TCP/IP and a specialized DEFINITY protocol to communicate.
The LAN link provides the same functionality as a DCIU link.
Note: The DEFINITY ProLogix Solutions system must have Release 7 or later
software and must be equipped with a C-LAN circuit pack (TN799). The
Lucent INTUITY system must be Release 4.4 or later and must be
equipped with a LAN interface card.