PYLE Audio 7505-BTSDCM PDAs & Smartphones User Manual


 
Appendix D: Bar Codes Settings
PDF-417
Ikôn Rugged PDA (Windows Mobile 6.1) User Manual D-35
Security Level
This parameter is used to differentiate between TLC-39 and standard Code 39. Tapping on
“Security Level” displays a dialog box in which you can assign a value from 0 to 100. The
higher the value assigned, the lower the decode rate.
Length Restriction
Refer to “Length Restriction” on page D-8 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page D-9 for details.
D.3.21 PDF-417
Enabled
Set this parameter to on to enable “PDF-417”.
Length Restriction
Refer to “Length Restriction” on page D-8 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page D-9 for details.
D.3.22 Micro PDF-417
Enabled
Set this parameter to on to enable “Micro PDF-417”.
Code 128 Emulation
When this parameter is enabled, the scanner transmits data from certain Micro PDF-417
symbols as if it was encoded in Code 128 symbols.
If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted
with one of the following prefixes:
]C1 - if the first codeword is 903-907, 912, 914, 915
]C2 - if the first codeword is 908 or 909
]C0 - if the first codeword is 910 or 911
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of
the following prefixes: