13.3 [11-3] Power Failure Transfer
When the power supply to the PBX fails, power failure transfer (PFT) switches the current connections to
Auxiliary Connections, so that certain SLTs and trunks can be connected. Auxiliary Connections allow trunk
calls
to
be made during a power failure. One trunk card and one extension card that are physically connected
by RJ45 cable can be specified. The conversations through the lines specified here will be maintained even
when the power returns.
Trunk Card Slot No.
Specifies the position of the trunk card to be used.
Value Range
None, Small Free Slot 1, Small Free Slot 2, Small Free Slot 3, Small Free Slot
4 (KX-NCP1000 only)
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Guide References
2.4.1 Power Failure Transfer
Extension Card Slot No.
Specifies the position of the extension card to be used.
Value Range
None, Small Free Slot 1, Small Free Slot 2, Small Free Slot 3, Small Free Slot 4 (KX-NCP1000 only)
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Guide References
2.4.1 Power Failure Transfer
PC Programming Manual 873
13.3 [11-3] Power Failure Transfer