ISDN CO / QSIG Master / QSIG Slave—T303
Specifies the
maximum time that the PBX waits for a reply after sending the SETUP (call setting) message to
ISDN.
Value Range
0–600 ´ 100 ms
Maintenance Console Location
3.30 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN CO / QSIG Master / QSIG Slave—T304
Specifies the maximum time allowed between each digit on an outgoing call. Applies to overlap sending.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.30 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN CO / QSIG Master / QSIG Slave—T305
Specifies the maximum time that the PBX waits for a reply after sending the DISC (disconnection) message
to ISDN.
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.30 [1-1] Slot—Card Property - BRI type/PRI type
254 PC Programming Manual
3.30 [1-1] Slot—Card Property - BRI type/PRI type