DISA Cyclic Tone Option—Tone Off Maximum Time
Specifies the
maximum time that the PBX waits for a cyclic tone to be sent from the telephone company before
recognising it as a tone-off. When no tone is detected within the time set here, the PBX recognises it as a
tone-off.
Note that this option can only be set when
DISA Cyclic Tone Detection on this screen is set to "Option".
To apply changes to this setting, follow the steps below:
1. Change this setting.
2. Set the status of the OPB3 card to "OUS", then "INS"
Value Range
10 ´ n (n=11–400) ms
Maintenance Console Location
7.3 [5-3-1] Voice Message—DISA System
Programming Manual References
3.1 [1-1] Slot
3.44 [1-1] Slot—OPB3 Card Property
Feature Guide References
None
DISA Cyclic Tone Option—Repeating Times of ON/OFF for Detection
Specifies the number of times the tone pattern (a set of tone-on and tone-off) must be received to establish
reception of the cyclic tone. This determines the end of call.
Note that this option can only be set when DISA Cyclic Tone Detection on this screen is set to "Option".
Value Range
3–16
Maintenance Console Location
7.3 [5-3-1] Voice Message—DISA System
Programming Manual References
None
Feature Guide References
None
Timed Reminder Message—Day, Lunch, Break, Night
Specifies the prerecorded message to play when a Timed Reminder call is answered in each time mode.
Value Range
None, 1–64
752 PC Programming Manual
7.3 [5-3-1] Voice Message—DISA System