When error detection (Mandatory): Send the Status Message when an error (Mandatory) is detected.
When error
detection (Option / Mandatory): Send the Status Message when an error (Option or Mandatory) is
detected.
Maintenance Console Location
3.33 [1-1] Slot—Port Property - PRI Port
Programming Manual References
None
Feature Guide References
None
Status Receive
Selects what happens to a call when the Status Message from the network does not match the actual status
of the call.
Value Range
Ignore: Ignore the Status Message from the network.
Disconnect: Disconnect the call.
Maintenance Console Location
3.33 [1-1] Slot—Port Property - PRI Port
Programming Manual References
None
Feature Guide References
None
CRC4 Mode
Enables the use of CRC4 for error checking. CRC (Cyclic Redundancy Check) is an error checking control
technique
that
uses a specific binary prime divisor that results in a unique remainder. It is usually a 16- to 32-bit
character. (Assignable only when using the PRI30 card.)
Value Range
Disable, Enable
Maintenance Console Location
3.33 [1-1] Slot—Port Property - PRI Port
PC Programming Manual 293
3.33 [1-1] Slot—Port Property - PRI Port