Description:
These messages indicate that the connection with the communication
server cannot be established. The IP Softphone 2050 sets a random retry
time, after which it attempts to reconnect. This process repeats until the
IP Softphone 2050 successfully connects.
The “Connecting...” message appears briefly (or not at all) under the
following conditions:
The communication server is running and reachable.
The IP Softphone 2050 is directed to the correct IP address.
The “Server unreachable” message appears when the IP Softphone 2050
encounters a problem contacting the communication server.
Potential causes:
Network down
Computer not connected to the network
Invalid communication server settings in the Configuration Utility
Invalid communication server settings in DHCP configuration
Communication server down
Action:
Ping another station on the network.
Ping the communication server.
Use the Server dialog box in the Settings window to verify the
communication server IP address and port number (for more
information, see “Server” on page 82).
Verify correct configuration of the communication server. Check for
the following: an available port, an available license, and for correct
security.