Nortel Networks MICS-XC Telephone User Manual


 
Installation / 21
P0881594 Issue 01 MICS-XC Norstar-Companion Installer Guide
RPI unit
There are two versions of the RPI unit: the RPI-8 BIX UL,
which supports up to eight Base Stations; and the RPI-16 BIX
UL, which supports up to 16 Base Stations. Each RPI has a
connection board and either one (RPI-8 BIX UL) or two (RPI-
16 BIX UL) power supply units (PSUs). The maximum input
power consumption of an RPI is 240 W. If a UPS 48 V DC
backup source is used, the maximum input power requirement
of the RPI is 135 W.
You can upgrade an RPI-8 BIX UL to an RPI-16 BIX UL by
installing a second PSU to the RPI-8 BIX UL. See “Upgrading
an RPI-8 to an RPI-16” on page 111.
If RPIs are distributed throughout the site, the number and type
of RPIs depend on the placement and powering plan of the
Base Stations.
To determine how many Base Stations and how many PSUs
you need for the number of Base Stations, use the following
table:
p0881594.book Page 21 Tuesday, August 25, 1998 3:59 PM