Troubleshooting / 101
P0881594 Issue 01 MICS-XC Norstar-Companion Installer Guide
A B2 channel radio (radio 2 on port 0103 in this
case) cannot be synchronized because the B1
radio was disabled in maintenance.
Both radios belonging to the Base Station (on port
0103 in this case) are disabled. The B1 radio must
be operational to synchronize both radios of the
Base Station with other radios in the system. Two
events are raised: one for the B1 channel radio and
another for the B2 channel radio. A corresponding
alarm code 53 occurs.
A radio (0103-1 in this case) cannot be
synchronized because there are no B2 channel
radios.
Both radios belonging to the Base Station (on port
0103 in this case) are disabled.Two events are
raised: one for the B1 channel radio in this case)
and another for the B2 channel radio. A
corresponding alarm code 53 occurs.
A recoverable RIM fault has occurred
The RIM is reset. If a link is active when this error
occurs, the link is dropped. The radio (0109-1 in this
case) is returned to service.
An unrecoverable RIM fault has occurred
The radio (0109-1 in this case) is disabled and
taken out of service. If a link is active when this error
occurs, the link is dropped. A corresponding alarm
code 53 occurs.
The built-in self-test on the Base Station has failed
The radio (0109-1 in this case) is disabled and
taken out of service. If a link is active when this error
occurs, the link is dropped. A corresponding alarm
code 53 occurs.
The Base Station is connected to a system that
supports a radio protocol that the ICS does not
understand.
There is a bad signature.
Event message display Cause
Evt:305-01032 S5
Evt:306-01031 S5
Evt:307-0109100 S5
Evt:307-0109101 S5
Evt:307-0109102 S5
Evt:308-0103 S5
Evt:664 S8
p0881594.book Page 101 Tuesday, August 25, 1998 3:59 PM