Nortel Networks MICS-XC Telephone User Manual


 
100 / Troubleshooting
MICS-XC Norstar-Companion Installer Guide P0881594 Issue 01
Event messages
Event message display Cause
(U.S. only) Unable to activate all registered
portables. The system ran out of portable credits.
One event is generated per portable that failed to
activate. The repetition of the corresponding alarm
code 59 indicates how many additional credits must
be purchased.
The Base Station (on port 0103 in this case) cannot
successfully receive the data image.
Both radios belonging to the Base Station are
disabled. This may occur if the flash EEPROM is
faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for the
B2 channel radio. A corresponding alarm code 53
occurs.
The Base Station (on port 0103 in this case) cannot
be written to during data transfer.
Both radios belonging to the Base Station are
disabled. The Base Station’s flash EEPROM is
faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for the
B2 channel radio. A corresponding alarm code 53
occurs.
The Base Station (on port 0103 in this case) cannot
be synchronized with the other Base Stations in the
system.
Both radios belonging to the Base Station are
disabled. The Base Station hardware is faulty. Two
events are raised: one for the B1 channel radio (as
in this case) and another for the B2 channel radio.
A corresponding alarm code 53 occurs.
A B2 channel radio (radio 2 on port 0103 in this
case) cannot be synchronized with other radios
because of system overload.
Evt:275-3546 S8
Evt:301-1031 S5
Evt:302-1031 S5
Evt:303-1031 5
Evt:304-1032