Multi-Tech Systems MVP-410ST/810ST IP Phone User Manual


 
MultiVOIP User Guide Technical Configuration (Analog/BRI)
245
FXS Loop Start Interface: Parameter Definitions (cont’d)
Field Name Values Description
Flash Hook Options fields
Generation --
not applicable to FXS interface
Detection
Range
for Min. and Max.,
50 - 1500
milliseconds
For a received flash hook to be
regarded as such by the
MultiVOIP, its duration must
fall between the minimum and
maximum values given here.
Pass Through
Enable
Y/N
When enabled, this parameter
creates an open audio path
through the MultiVOIP.
If the Pass-Through feature is
enabled, the AutoCall feature
must be enabled for this voip
channel in the Voice/Fax
Parameters screen.
Caller ID fields
Caller ID Type Bellcore
The MultiVOIP currently
supports only one
implementation of Caller ID.
That implementation is Bellcore
type 1 with Caller ID placed
between the first and second
rings of the call.
Caller ID
enable
Y/N
Caller ID information is a
description of the remote
calling party received by the
called party. The description
has three parts: name of caller,
phone number of caller, and
time of call. The ‘time-of-call’
portion is always generated by
the receiving MultiVOIP unit
(on FXS channel) based on its