Axis Communications A8004-VE Intercom System User Manual


 
AXIS A8004-VE Network Video Door Station
Events
To use the recurrence in an action rule, rst select Time from the Trigger drop-down list in the Action Rule Setup page and then
select the recurrence from the second drop-down list.
To modify or remove recurrences, select the recurrence in the Recurrences List and click Modify or Remove.
Pre-congured Action Rules
The Axis product is pre-congured with a set of action rules in order to simplify different setup requirements.
AUDIO: Calling - Triggers the Action rule when a call service state changes to calling. An audio clip is played when a call is connecting.
AUDIO: Stop on Active call - Triggers the Action rule when a call service state changes to active. An active audio clip is stopped
when a call is answered.
AUDIO: Stop on Idle call - Triggers the Action rule when a call service state changes to idle. An active audio clip is stopped when
all calls end.
BUTTON: VMS call - Triggers the Action rule when digital input port is active. A call request is made to a Video Management
System (VMS) recipient.
DOOR: REX unlocks - Triggers the Action rule when digital input port is active. A door connected to relay 1 can be accessed (door
unlocked for 7 seconds and is then relocked, this time can be changed in the Action Rule Setup) when the output port is activated.
LIGHT: Active call - Triggers the Action rule when a call state changes to active. The built-in illuminator fades to 90% intensity
when a call is ongoing.
LIGHT: Calling - Triggers the Action rule when a call state changes to calling. The built-in illuminator ashes when a call
is connecting.
LIGHT: Idle - Triggers the Action rule when a call state changes to idle. The built-in illuminator fades to 10 % intensity when a
call ends.
TAMPERING: Casing open - Triggers the Action rule if the front cover is removed. When the output port is activated, the AXIS 9801
security relay box (not included) connected to Port 4 will lock itself down to prevent any malicious person from short circuiting
the lock/device/door connected to it.
TAMPERING: Shock detected - Triggers the Action rule if the Axis product detects it has been tilted or hit. When the output port is
activated, the AXIS 9801 security relay box (not included) connected to Port 4 will lock itself down to prevent any malicious person
from short circuiting the lock/device/door connected to it. It is recommended to tune the shock detection level or turn off this rule if
the door station is installed on materials that are prone to movements, for example, plaster walls, posts and metal sheets.
51