Agilent Technologies 5071A Wireless Office Headset User Manual


 
Specifications
Supplemental Characteristics
3-2
Supplemental Characteristics
This section describes the additions, changes, and deletions to the
information that appears in the Supplemental Characteristics section
of the Specification chapter for either the HP 5071A Operating and
Programming manual or the HP 5071A Assembly-Level Service
manual.
Time Standard
Clock 1 PPS Outputs
All references to 1 PPS Outputs are singular.
Clock Synchronization
The 2nd sentence is changed:
Sync pulse: front-panel input; may be armed via remote command or
front-panel keystrokes.
Internal Standby Battery (Nominal Values)
Delete all Internal Standby Battery specifications when the 48 Vdc
Power option is present.
Environmental
Power Requirements
The following items under Input Power (nominal) are changed:
dc: Primary power source; unit will draw dc power in preference to ac
power.
The following items under Input voltage: dc: are changed:
dc: 40-58 Vdc operating for option 048.
Damage level: 72V.
The maximum allowable volt-age between either input terminal and
chassis is 60V.
Any TCO Option:
Any TCO Option:
Option 048:
Option 048:
Option 048: