1.4.4.2.1 A1C4 Voltage Test Procedure
The
QUESTION, is changed to:
Is the voltage between 45 and 51 Vdc?
1.4.4.3 LF1/T1 Transformer Fault Verification
Step 2 text is changed to:
Verify presence of 33 - 47 Vrms.
The QUESTION: is changed to:
Is the voltage between 33 - 47 Vrms?
The T1 part number within
If No response text to the QUESTION., is
changed to:
(9100-5134)
Advisory Messages (Subsection 7)
1.7.1 Advisory Message Interpretation
Advisory Message: SAW Osc unlocked is deleted,
Functional-Group Diagnostic Trees
(Diagnostic Section 2)
1 Power-Supply Diagnostic Tree: 2.1.1.1.0
The bulleted item B1 24V Internal-Standby Battery on page 2-45 is deleted.
Power-Supply Diagnostic Tree
(Functional Group Subsection 1)
The bulleted item B1 24V Internal-Standby Battery on page 2-46 is
deleted.
2.1.1.1.1 A12 Power Input Test
Step 2 4 text is changed to:
Verify that the voltage present is between 45 and 51 Vdc with no
more than 1 Vrms ripple.
The second sentence of the
If No response to the first QUESTION: is
changed:
b) Verify that the voltage present is between 45 and 51 Vdc with no
more than 1 Vrms ripple.
Option 048:
Option 048:
Any TCO Option:
Option 048:
Option 048: