TOA Electronics CP-66 Intercom System User Manual


 
EXES-6000 CP-66 — Summary of Dialing Operations (single exchange system)
1. Selecting dial operations
The EXES-6000 Intercom system allows digit-dialing operations to be minimized depending on the number of stations and
their functions. Four types of dialing operations (Type 1, Type 2, Type 3, and Type 4) are available. Select the most suitable
type by changing the setting of the internal switch at the exchange. The following explanations describe the dialing operation
when the switch is set for Type 2. For other types, check the dial operation while referring to the attached lists.
[Four types of dialing operations]
Type
Type 1
Type 2
Type 3
Type 4
Feature
Three-digit dialing
Standard type
Maximum of 128 stations
(without paging)
Maximum of 120 stations
(with all station call + 7-zone paging)
Three-digit dialing
Station number conversion
Maximum of 256 stations
Two-digit dialing
Full paging function
Maximum of 70 stations
(with/without paging)
Two-digit dialing
Maximum of 90 stations
(with/without paging)
Numbering plan
Standard type
No. 200 ~ 327
No. 100 ~ 227)
Station number conversion
No . 20 0 ~ 3 99
(No. 100 ~ 399)
Standard type
No. 200 ~ 455
(No. 100 ~ 355)
Station number conversion
No. 200 ~ 999
(No. 100 ~ 999)
Standard/station number conversion
No. 20 ~ 79
(No. 10 ~ 79)
Standard/station conversion
No. 20 ~ 99
(No. 10 ~ 99)
— 20 —