Phonetics 1104 Telephone User Manual


 
Sensaphone
®
Model 1104 Users Manual
50
NOTE
Before starting keyboard commands to configure
input normality on the Model 1104, it is very
important to check that the sensors you have
wired to the unit are set in their normal, non-
alarm positions. For example, if a magnetic reed
switch (a normally-closed sensor used to detect
unauthorized entry) has been wired to the
Model 1104, make sure that the door or window
to be monitored is shut before configuring the
input. If a motion-detector is wired to the unit, it
is advisable to block all sources of motion from
the sensor before and during configuration.
5.1.1 Programming Input Configuration
1. Press STANDBY to place the Model 1104 in
Standby mode.
2. Wire sensors to the inputs to the back of the Model 1104
(see Chapter 2, Section 2.10).
3. Press RUN. The red light glows when the Model 1104
returns to Run mode.
4. Press SET.
5. Press CONFIGURE.