Avaya IP Office Phone IP Phone User Manual


 
Technical Data Cables - Page 75
IP Office Installation Manual Technical Data - Page 75
40DHB0002USCL – Issue 9 (28th October 2003) Cables
X.21 WAN Cable
SAP Code:- 700213408
A
B
C D
E
A 37 Way D-Type Plug with UNC 4-40 locking screws.
B 15 Way D-Type Plug with M3 locking screws.
C Label
D 6 twisted pair screened cable - each core is 7/0.203mm (24 AWG) tinned copper
stranded wire, nominal capacitance of 98pF/m, impedance of 77 at 1MHz, screened
with aluminized tape and a tinned copper wire drain.
E 3 meters/9.84ft.
Pin Connections
End A Name Cable Notes End B
1 Receive (Rx-B) 11
20 Receive (Rx-A)
Twisted Pair
4
4 Transmit (Tx-A) 2
23 Transmit (Tx-B)
Twisted Pair
9
24 Control (Ctl-A) 3
5 Control (Ctl-B)
Twisted Pair
10
2 Indicate (Ind-A) 5
21 Indicate (Ind-B)
Twisted Pair
12
3 SE-Timing (S-A) 6
22 SE-Timing (S-B)
Twisted Pair
13
6 Ground ------ 8
Connect pin 7 to pin 6 at End A only.
Pin 19 at end A is connected to the Screened Cable Drain Wire.
This cable is used to connect a WAN port to a Digital leased Line.