Mitel 3000 IP Phone User Manual


 
Mitel 3000
Getting Started Guide
27
Additional Extension Settings
The following parameters may be also be set on an extension-by-extension basis. Refer to the
full “Administrator’s Manual” for detailed programming instructions if required.
25 Hz
This allows the ringing frequency to be changed from 50 to 25 Hz.
The default setting is 50Hz however some older phone equipment
may require 25 Hz for ringing. This setting should only be applied if a
telephone does not ring correctly at 50 Hz.
3.1 kHz Station
Allows an outgoing call to be set for 3.1Khz minimum bandwidth. It is
advisable to set this for Fax or Modem calls out over ISDN lines
Extension Disconnect
No dial tone is supplied to the extension and it cannot be used. This
is generally used if an unoccupied office is equipped with a phone
that will be turned on for use at some future date.
Hot Line
Allows an extension to be set to call a pre-programmed number
when the extension goes off hook. Typically used for unsupervised
reception areas or fax machines.
Individual Caller ID
Lists
The Administrator can decide which extensions have individual
Caller ID Lists.
Keypad Confirmation
Allows the keypad tones to be switched on/off on an extension-by-
extension basis.
Manager/Assistant
Allows specific features to be mapped between a manager and
assistant for improved functionality.
No Call Logging
Prevents calls to and from this extension being stored in the Station
Message Detail Recorder (SMDR) log.
External Diversions
This prevents or allows extensions to forward their calls externally. It
also allows or prevents an extension from using external transfer or
conference with two lines and an extension.
Open Door Restriction
An extension can be restricted from opening the door if a remote
door opening system is installed.
Page Protect
Removes an extension from the paging group.
Port Swapping
Allows two extensions to be swapped on the system for
administration or programming purposes.
Permanent CLIR
Allows a station to be set so that it never sends the CLI number
when making an outgoing call (CLIR)
Permanent COLR
Allows a station to be set so that it never shows the CLI number
during a connected incoming call (COLR)
Restrict use of PA
Prevents an extension from accessing the optional PA system if
connected to the system.