*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
5 - 20
UX-910 ADJUSTMENTS (continued)
APC
(POWER SET)
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
3
4
5
• Display frequency: 1270.0000 MHz
• Mode : CW
• Connect an SSG to the check point
CP311 and set as :
Frequency : 10.8500 MHz
• Transmitting
• Transmitting
• Transmitting
• Transmitting
• Transmitting
Rear
panel
MAIN
(UX-910)
Rear
panel
MAIN
(UX-910)
Connect an RF
power meter to [12
ANT].
Connect a digital
multimeter or oscillo-
scope to check point
CP15.
Connect an RF
power meter to [12
ANT].
Connect a digital
multimeter or oscillo-
scope to check point
CP401.
Connect a digital
multimeter or oscillo-
scope to check point
CP15.
13 W
3.0 V
10.5 W
3.1 V
3.0 V
MAIN
(UX-910)
MAIN
(UX-910)
MAIN
(UX-910)
Adjust
SSG’s
level
R37
Adjust
SSG’s
level
R67
R61