D-Link KX-TDA100 Telephone User Manual


 
4.1 Troubleshooting
232 Installation Manual
System Start-up and On-line Operation
Error Code Error Message PROBABLE CAUSE SOLUTION
000* MPR WDT overflow MPR card malfunction
Optional service card
malfunction: CTI-LINK
Erroneous processing of
MPR card software
Software error due to
external factors
Press the Reset Button
Reprogramme the Hybrid IP-PBX
Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)
001 SDRAM bit error
002 System Restart Reset Button is pressed
Power failure
MPR card malfunction
Erroneous processing of
MPR card software
Software error due to
external factors
Ignore if not frequent
Press the Reset Button
Reprogramme the Hybrid IP-PBX
Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)
010* AC power down Power supply system
malfunction (e.g., power
failure, power noise,
trouble with UPS)
Bad connection or
breaking of AC cord
Power supply circuit (PSU,
back board) malfunction
Check the power supply system
See if the AC cord is connected
properly
Check the AC cord
Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)
Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)
Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)
011* DC power down AC power down
Power supply circuit (PSU,
back board) malfunction
Detection of over current
(short circuit on optional
service cards)
Check the power supply system
See if the AC cord is connected
properly
Check the AC cord
Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)
Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)
Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)
Remove the optional service cards and
restart the Hybrid IP-PBX
012* MPR RAM battery
low
Battery out
MPR card malfunction
Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)
014* FAN Alarm PSU-L malfunction See if anything is jammed in the fan
Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)