2.13 Starting the Hybrid IP-PBX
210 Installation Manual
2. Plug the AC power cord into the Hybrid IP-PBX and an AC outlet, and turn on the Hybrid IP-PBX. The
RUN indicator will flash.
Note
For safety reasons, do not stretch, bend, or pinch the AC power cord.
3. While the RUN indicator is flashing, return the System Initialise Switch to the "NORMAL" position.
Depending on the configuration, initialisation takes about 1 min to 3 min. If successfully executed, the
RUN indicator will stop flashing and be kept lit.
All data will be cleared, and the Hybrid IP-PBX as well as all optional service cards (except for the IP-GW
card) will be initialised to the default values. The DPTs should show the time as 01:00.
The data of the IP-GW card will not be initialised.
Notes
Use only the AC power cord included with the Hybrid IP-PBX for the PSU.
Use only the supplied AC power cord for the purpose of applying the EMC standard, if the Hybrid
IP-PBX is connected (Germany only).
LED Indications
Confirming the Trunk Connection
After initialisation, programme the Hybrid IP-PBX and establish trunk connection, and then use a PT to
confirm it.
Indication Colour Description
RUN Green PBX status indication
OFF: Power Off (includes normal reset)
ON: Power On and running (on-line)
Flashing (60 times per minute): Starting up
Flashing (120 times per minute): Starting up or resetting with:
the System Initialise Switch in "SYSTEM INITIALIZE"
position
the SD Memory Card not inserted
ALARM Red Alarm indication
OFF: Normal
ON: Alarm (CPU stop, alarm for each card)
Flashing: Alarm (MPR file error in restarting)
To AC Outlet