ClearOne comm XAP 800 Conference Phone User Manual


 
Installation ~ LCD Programming
14
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
The five main menus are: System, RS-232, Meter, Inputs, and Outputs. All
submenu items are arranged under these menus. Use the Enter button to select items
and the and buttons to scroll through menus and submenus.When the last
menu item is reached, the display scrolls back to the beginning of the list.The Esc
button allows you to back out of the menus.
To adjust a parameter
1. Scroll to the parameter you want to adjust. Press Enter to select the
parameter.The parameter will flash when selected.
2. Adjust the value with the and buttons. As the value is adjusted, the
parameter is updated immediately.
3. To store the new value, press Enter.To discard the change and revert back
to the old value, press Esc.
If the Meter button is pressed while a parameter is being adjusted, the LCD
will switch to the Meter menu.
System menu
There are eight system-level parameters (see Figure 2.6): Select Preset, Run Macro,
Lock Panel, Set Passcode, Device ID, Mixer Mode, Unit ID, and Firmware Version.
Select Preset
The Select Preset menu item allows for one of 32 preprogrammed presets to be
selected for XAP 800 use.To select a preset, scroll through the numbered presets
(1–32) until the desired preset is visible, then press Enter to run the preset.
Run Macro
The Run Macro menu item allows you to execute a macro.To select a macro, scroll
through the numbered macros (1–255) until the desired macro is visible, then press
Enter to run the macro.
Lock Panel
The front panel may be locked to prevent unauthorized adjustments to the XAP 800.
To lock the front panel, use the /buttons to select Lock Panel from the System
menu, and press Enter. Lock Panel selections are Off, On, or On at Timeout. Press
Enter to enable your selection.