126
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
SIGTOUT - Signal Generator Time Out
Sets the signal generator time out for the unit.
Command form: DEVICE
SIGTOUT
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
SIGGEN Command
Value 0 = Off, 1–30 = Set time out minutes, Null = Current rate
Example:
#57 SIGTOUT 15
On XAP 800 unit 7 (
#57
), the signal generator
time out (
SIGTOUT
) is set to
15
minutes.
SLVL - Speech Level Control Enable/Disable
This command selects/reports the setting of speech level control for a microphone.
Command form: DEVICE SLVL <Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
SLVL Command
Channel 1–8 (select mic input)
Value 0 = Off, 1 = On, 2 = Toggle, Null = Current mode
Example:
#50 SLVL 2 M 1
On XAp 400 unit 0 (
#50
), the speech leveler for mic
(
M
) channel
2
is set to on (
1
).
STRING - String Execution
This command sends the specified string out the serial port.
Command form: DEVICE
STRING
[ID]
Argument details
Name Description
Device 0–7 or * to select all units
STRING Command
ID 0 – 7
Null to query last string in text
Example:
#51 STRING 3
On XAP 800 unit 1 (
#51
), the
STRING
programmed
into location
3
will be sent out the RS-232 port.
The serial command to
create a string is
PRGSTRING (Program
String). See page 122.
✍✍