ClearOne comm XAP 800 Conference Phone User Manual


 
MINIT - Modem Initialization String
This command sets/reports the modem initialization string of the serial port when in
modem mode.
Command form: DEVICE MINIT [String]
Argument details
Name Description
Device 0–7 or * to select all units
MINIT Command form
String 1-80 characters (select string characters to be sent to the modem
when the unit is initialized
CLEAR = clears the modem initialization string
Null = Current string
Example:
#56 MINIT ATZ
On XAP 800 unit 6 (
#56
), the modem initialization
string (
MINIT
) is
ATZ
.
MINMAX - Minimum and Maximum Gain Setting
This command changes or reports back the minimum and maximum gain setting for
an input, output or assignable processing block.
Command form: DEVICE
MINMAX
<Channel> <Group> [Minimum] [Maximum]
Argument details
Name Description
Device 0–7 or * to select all units
MINMAX Command form
Channel See Groups and Channels
Group I, O, M, P, L
Minimum -65.00 to 20.00, Null to return current settings
Maximum -65.00 – 20.00
Example:
#55 MINMAX 2 M -12 10
On XAP 800 unit 5 (
#55
), the minimum
and maximum (
MINMAX
) relative gain settings for mic (
M
) channel
2
are
-12
dB
and
10
dB respectively.
116
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands