MACRO - Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed.There
are 255 macros that can be specified.
Command form: DEVICE
MACRO
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
MACRO Command form
Value 1-255 Value to execute user macros
Example:
#55 MACRO 1
On XAP 800 unit 5 (
#55
), Macro (
MACRO
)
1
is run.
MASTER - Expansion Bus Master Mode
This command reports the mode of the unit.The mode can be Master or Slave.
Command form: DEVICE
MASTER
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
MASTER Command form
Value 1 = Master, 2 = Slave, Null = Current mode of the unit
Example:
#56 MASTER 2
On XAP 800 unit 6 (
#56
), the
MASTER
mode is set
to slave (
2
)
MAX - Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input,
output or assignable processing block.
Command form: DEVICE
MAX
<Channel> <Group> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
MAX Command form
Channel See Groups and Channels, page 97
Group I, O, M, P, L
Value -65.00 to 20.00 dB
Null to return the current setting
Example:
#51 MAX 2 M 10
On XAP 800 unit 1 (
#51
), the maximum (
MAX
)
relative gain setting for mic (
M
) channel
2
is
10
dB.
114
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
The response indicates
execution of the macro,
but does not indicate that
each command within the macro
was executed.
✍✍
This setting will affect all
relative gain adjustments.
✍✍