Avaya Definity Gx/PBXLink Integration Guide for Cisco Unity 4.0
OL-3105-15
Avaya Definity Gx/PBXLink Integration Guide for Cisco Unity 4.0
Requirements
Task List to Make Changes to an Integration
Use the following task list to make changes to an integration after it has been created.
1. Start the Cisco Unity Telephony Integration Manager (UTIM). See the “Changing the Settings for
an Existing Integration” section on page 40.
2. Make the changes you want to the existing integration. See the “Changing the Settings for an
Existing Integration” section on page 40.
Task List to Delete an Existing Integration
Use the following task list to remove an existing integration.
1. Start the Cisco Unity Telephony Integration Manager (UTIM). See the “Deleting an Existing
Integration” section on page 41.
2. Delete the existing integration. See the “Deleting an Existing Integration” section on page 41.
Requirements
The Avaya Definity/PBXLink integration supports configurations of the following components:
Phone System
An Avaya Definity phone system with one or two digital lines connected to the PBX ports on the
PBXLink box. The line or lines must be compatible with the 7434D or 8434D digital phones. If
vectoring will be used and depending on the phone system, the line or lines may require
compatibility with only the 7434D digital phone.
Bridged mode feature, enabled.
For each voice messaging port, one analog port connected to the voice cards in the Cisco Unity
server.
The SMDI port in the PBXLink box connected to a serial port (COM1 is the default) on the
Cisco Unity server with an RS-232 serial cable. If multiple PBXLink boxes are installed, the SMDI
port of the last PBXLink box is connected to the Management port of the first PBXLink box with
an RS-232 serial cable. The SMDI port of the first PBXLink box is connected to a serial port (COM1
is the default) on the Cisco Unity server with another RS-232 serial cable. Make sure that the serial
protocol parameters for the Management port of the first PBXLink box are set to the same values as
the SMDI port.
We recommend that the serial cable have the following construction:
A maximum of 50 feet (15.24 m) in length
24 AWG stranded conductors
Low capacitance—for example, no more than 12 pF/ft (39.4 pF/m) between conductors
At least 65 percent braided shield over aluminized polymer sleeve around conductors
UL-recognized overall cable jacket insulation with low dielectric constant
Braided shield fully terminated to and enclosed by a metal connector backshell
Gold-plated connector contacts