Anritsu MT8850A Bluetooth Headset User Manual


 
13000-000109 3-1
June 2003 Introduction
Chapter 3. Installation
Introduction
This chapter provides information for the initial inspection and preparation for use of the
MT8850A/MT8852A Bluetooth Test Set. Shipping and storage information is also
included.
Initial Inspection
Inspect the shipping container for damage. If the container or cushioning material is
damaged, retain until the contents of the shipment have been checked against the packing
list and the instrument has been checked for mechanical and electrical operation.
If the Test Set is damaged mechanically, notify your local sales representative or Anritsu
Customer Service Center. If either the shipping container is damaged or the cushioning
material shows signs of stress, notify the carrier as well as Anritsu. Retain the shipping
materials for the carrier's inspection.
Power Requirements
The MT8850A/MT8852A Bluetooth Test Set is operated from AC line power. The
MT8850A/MT8852A is intended as an Installation (Overvoltage) Category II, Insulation
Category I device.
At power-on, the instrument will perform a brief power-on self test (POST). If a POST error
occurs, information and available options will be displayed on the screen. If the POST is
successful, the instrument will then go to the top-level script or single test screen that was
active when it was powered down.
AC Line Power
The MT8850A/MT8852A can operate on AC input power of 85-264V, 47-63 Hz, 150 VA
maximum. The Test Set automatically configures itself for the voltage applied. An internal
fuse protects the AC line input.
Fuse Protection
The MT8850A/MT8852A Bluetooth Test Set is protected on the AC input by an internally
mounted fuse. Only qualified service personnel should change this fuse. Replace only with
a fuse of the same type and rating, which is 5 mm x 20 mm, 250V, 2.5A T (T= time lag or
slo-blo).
Grounding
The MT8850A/MT8852A Bluetooth Test Set must be properly grounded. Failure to ground
the instrument could be hazardous to operating personnel. The instrument is supplied with
a three-wire power cord.
The instrument is properly grounded when the plug is correctly installed in a grounded
receptacle. A grounding terminal is provided on the instrument rear panel.