Using the Script Menu MT8850A / MT8852A Bluetooth Test Set
Initial Carrier Test (Single Payload Mode)
The initial carrier test performs a frequency accuracy test on a DH1 pseudo random data
packet. (PRBS 9) This test can be performed using either the loopback test control or the
TX test control. The default is to use the loopback test control. This test can be made with
either hopping on or off.
1. Refer to the settings below to enable the initial carrier test in the test list.
Test control: TX or Loopback
Payload: Any
Packet type: Any
Hopping mode: On or Off
2. Choose “Init carrier” from the Script menu.
3. Press the
key to select or deselect this test from the script routine.
4. If a test is selected, the box will be filled in. If not selected the box will be hollow.
5. Press the
[Setup] soft key.
6. The Initial carrier test limits screen is displayed.
7. Press the
[Defaults] soft key to restore the default values.
8. Choose the limit you want to change.
9. Press the
key and enter the new limit using the keypad.
10. Press the
[Enter] soft key.
11. Press the
key to return to the Script menu.
13000-000109 8-35
June 2003 Testing in Single Payload Script Mode